Control Channel Loop-Around Test (#52)
This nondestructive test fails if the circuit pack does not return to a sane state after being reset.
This test queries the circuit pack for its code and vintage, and verifies its records.
Table 270: Test #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
None,
2100
ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
FAIL The circuit pack failed to return the code or vintage.
1. Retry command at 1-minute intervals up to 5 times.
2. Reset the board with reset board location.
3. If reset aborts with error code 1115, busyout (busyout board
location), reset with reset board location, and release board
(release board location).
4. If test continues to fail, replace the circuit pack.
5. Escalate the problem if failures continue.
PASS Test successful.