HYB-LINE (Hybrid Line)
Issue 1 June 2005 1335
Hybrid Electronic Power Feed Test (#56)
In this test, the software requests that the EPF be turned on for a given port. Then hardware
attempts to turn on the power unit from the station. If no current is drawn, the station is probably
not connected. If an overturned condition is sensed (that is, too much current is being drawn),
this may indicate a short in the loop or a defective voice terminal. A message is returned stating
that either the EPF was turned on successfully, or that an overcurrent condition exists. This test
is repeated once more 5 seconds later. If either test is not successful, the test will abort (see first
ABORT entry in Table 466: Test #56 Hybrid Electronic Power Feed Test
on page 1335).
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 465: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 4
Table 466: Test #56 Hybrid Electronic Power Feed Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3