Communication Manager Maintenance-Object Repair Procedures
1032 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1015 ABRT Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter busyout board location to put all trunks or ports of the DS1
Interface circuit pack into the out-of-service state.
2. Retry the command.
1039 ABRT The DS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the DS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the Tone-Clock circuit
via the following command sequence:
1. Enter disable synchronization-switch
2. Enter enable synchronization-switch set
synchronization location
3. Enter enable synchronization-switch
1950 ABRT Another loop-back/span test is already executing on the DS1 board or the
board is in a network requested loop-back mode (Line loop back or Payload
loop back). The hardware error log indicates whether a Customer Loopback
Jack test, Far CSU Loopback test, or the One-Way Span test is executing or
if the board is in line loop-back or payload loop-back mode. Only one
long-duration loop-back/span test can be active at a given time. Thus, if a
loop-back/span test is already active, that test must be deactivated via test
ds1-loop location end-loopback/span-test in order to execute
this test.
1951 ABRT The CSU Repeater Loopback test could not be executed because the 120A
CSU module/T1 sync splitter was not physically installed. Physically connect
the 120A1 CSU module/T1 sync splitter to the TN767E board on the back of
the port carrier.
Table 355: Test #1211 CSU Repeater Loop-Back Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4