Communication Manager Maintenance-Object Repair Procedures
954 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0
: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 1
Aux Data 57408: No tip ground is detected on an outgoing call.
Aux Data 57476:
Rotary Dial before Wink.
Aux Data 57477:
Rotary Dial pulse too early.
Aux Data 57485:
Wink too short for a valid signal.
Aux Data 57487:
PBX could not get “loop close” signal.
The DS1 Interface circuit pack detected a hardware fault. These errors will cause the Dial
Tone test (#314) to run and are only considered a problem if the Dial Tone test fails (in which
case Error Type 1025 will also show up). In this case, the trunk may be put in the
ready-for-service state (shown as “disconnected” by the status command), which allows
only incoming calls. Run the Dial Tone test (#314) and follow the procedures.
1025 DS1 CO Dial
Tone Seizure
(#314)
MIN
WRN
2
OFF test trunk grp#/mem# r 2
1281 Conference
Circuit test (#7)
MIN
WRN
2
ON test trunk grp#/mem# l r 4
1537 NPE Crosstalk
test (#6)
MIN
WRN
2
ON test trunk grp#/mem# l r 3
1793 (j
) test board location l
2049 (k
) 57473
57474
57475
2305 (l
) 50944
2562 (m
) 16665
2817 (n
) 52992
3840 (o
) Port Audit and
Update (#36)
1. This alarm is raised when the Base Tone Generator field is 4 (Italy) on the System-Parameter
Country screen. This alarm is MINOR unless 75% or more trunks in this trunk group are out of service, then
the alarm is upgraded to a MAJOR alarm.
2. Major alarms may be downgraded to Warning alarms based on the value used in set options.
Table 326: DS1 DIOD Trunk Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2