Communication Manager Maintenance-Object Repair Procedures
2354 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: A failure in the tone generation facility on the indicated circuit pack has been
detected. Replace the circuit pack. See Replacing the IPSI or Tone-Clock Circuit Pack
on
page 2337.
c. Error Type 18: the IPSI or Tone-Clock circuit pack has been made unavailable using
busyout tone-clock location. It only applies to systems which have the high- or
critical-reliability option administered, because only a standby Tone-Clock circuit may be
made busy by that command. To resolve this error, execute release tone-clock
location for the alarmed circuit pack.
Note:
Note: IPSI circuit packs require the location qualifier; Tone-Clock circuit packs do
not.
d. Error Type 130: the circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, reinsert or replace the circuit pack.
e. Error Type 257: the tone generation facility is having problems verifying that tones have
been connected as requested
f. Error Type 513: The tone generation facility may or may not be able to generate tones.
18 (c
) 0 busyout tone-clock location WRN OFF release
tone-clock
location
130 (d
) None MIN ON test tone-clock
location sh
257 (e
)(g) 17667 None MIN ON
513 (f
)(g) 17666 Tone Generator Audit/
Update (41)
MIN ON test tone-clock
location r 3
1281 (h
) Any Tone Generator Audit/
Update (41)
MIN ON test tone-clock
location r 3
1. IPSI circuit packs require the location qualifier; Tone-Clock circuit packs do not.
2. MAJOR alarm if the alarmed IPSI or Tone-Clock circuit pack is not duplicated; MINOR if it is duplicated
within the same PN.
Table 842: Tone Generator Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2