DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005 907
1018 ABRT Test disabled by administration. Verify that the Maintenance Tests? field
on the Trunk Group form is set to n. To enable the test, enter change
trunk-group x (x is the trunk group number). Enter y in the
Maintenance Tests field.
S8300 /
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available. This may be
due to the port being seized.
1. This abort code is usually associated with tone-clock (TONE-BD,
TONE-PT, and TDM-CLK) resources. Clear any tone errors in the
error log.
2. Retry the command at 1-minute intervals up to 5 times.
3 FAIL The nonreflective 1004-Hz tone test of the port failed. An echo was
detected from the port. Poor-quality transmission was detected to or from
the port. The problem may be off-board. See additional information for this
error code below.
!
CAUTION:
CAUTION: The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems include
incoming seizures or off-hook port seizures during the test
and, perhaps, noise induced by adjacent electric power
lines. The test may be disabled from the trunk
administration 'Test' field. This turns off all testing for that
trunk group except for tests 6 and 36.