This error is most likely due to a problem with the wiring to the set or adjunct, interference
on the wiring due to a noise source, or no termination (an open circuit). It usually does not
indicate a problem with the circuit pack.
● Check the wiring to the endpoints or the adjunct.
● If the problem persists, replace the endpoints or adjuncts, or escalate the problem.
i. Error Type 1793: the BRI Port Local TDM Loop Around test (#619) fails. Run the long test
sequence, and pay particular attention to the results of Test #619.
There are no Test to Clear Values for the following error types. The error types are simply
provided as additional data that may prove useful while troubleshooting.
j. Error Type 3841: a Layer 1 Transmission error is detected for the port. Run the long test
sequence, and pay particular attention to the results of the Layer 1 Transmission Error
Counter test (#624).
k. Error Type 3842: A BRI port supports up to three Terminal Endpoint Identifiers (TEIs). This
error occurs when the switch receives a request for a fourth TEI on a port. Check the
number of endpoints administered for this port.
l. Error Type 3843: a SPID initialization request is made from an endpoint and the switch
determines that the SPID value is invalid or is a duplicate of another SPID that is already
initialized at Layer 3 on the port. Check the administration of the endpoints.
m. Error Type 3844: the circuit pack detects an overflow of its receive buffers. Run the long
test sequence, and pay particular attention to the results of the Receive FIFO (First In First
Out) Overflow Error Counter test (#625).
n. Error Type 3845: the BRI Port Local LAN Loop Around test (#618) fails. Run the long test
sequence, and pay particular attention to the results of Test #618.
o. Error Type 3846: most likely occurs when the Terminal Endpoint Identifier (TEI)
administered for the ASAI or Avaya endpoint does not match the TEI administered in the
ASAI or Avaya adjunct. Check the switch administration of the TEI against that of the
adjunct and make sure that both are using the same TEI.
p. Error Type 384: sets on the port do not support layer-3 initialization. Consult the Service
Set documentation.