ERR-LOG (Error Log)
Issue 1 June 2005 1145
ERR-LOG (Error Log)
S8700 | 8710 / S8500
The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware Error Log, and
the Software Error Log. If an inconsistency is detected in any one of these logs, every log will be
re-initialized and a hardware error will be logged against ERR-LOG indicating the time of
inconsistency. There are no tests and no alarms for the Error Log MO. This MO exists solely for
the purpose of allowing errors to be logged against it.
Hardware Error Log Entries
Notes:
a. Error Type 510: An inconsistency was detected in either the Alarm Log, the Hardware Error
Log, or the Software Error Log. The system attempts to recover the logs but, depending on
the extent of the corruption, some or all entries in the logs may be lost. Any alarms that were
active at the time of this error have been cleared. There is no associated test for this error.
The Aux Data value indicates when the inconsistency was found:
MO Name in Alarm Log Alarm Level Initial Command to Run Full Name of MO
ERR-LOG none none Error Log
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
510 (a
) See Note none none none none
0 During a periodic audit of the Error Log
1 After an extended reboot
2 After a reboot
3 After a Reset System 3 (Cold_1)
4 After a Level-3 System Reset (Cold_1)
4 After a Reset System 2 (Cold_2)
8 After a Level-2 System Reset (Cold_2)
16 After a Level-1 System Reset (Warm Start)
100 After an internal software audit
2500 After a single-process (MDM) restart