EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005 1209
2000 ABRT Response to the test request was not received within the allowable
time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL The test tone was not detected correctly in either direction.
1. Run the test for the active Tone-Clocks on the PNs for which the
EI circuit pack under test provides a link. This will determine
whether dial tone is being supplied.
2. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192).
1 or 2 FAIL The test tone was detected correctly in one direction, but not the
opposite direction.
1. Test for the active Tone-Clocks on the PNs for which the defective
EI board provides a link. This determines if the dial tone is
supplied.
2. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192).
Center Stage: These failure codes are possible on a Center Stage
Switch configuration only when there is just one other PN available for
looping back the test tone.
1. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192).
Table 412: Test #241 Expansion Interface 2-Way Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation