FIBER-LK (Fiber Link)
Issue 1 June 2005 1261
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABRT SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.
2306 ABRT A fiber link’s SNI circuit pack is not responding to test requests sent by
software.
1. Run test led switch-node for the switch node where the SNI
board(s) reside to verify whether their LEDs light. If not, continue with
the following steps.
2. If LEDs light on other boards in the same carrier (but not on this board),
enter test board location l (#760) for the active SNC in this
carrier. Wait 5 minutes, and try step 1 again. If the board’s LEDs still do
not light, replace the board. (Replacing an SNI may be service
interrupting. Refer to the SNI-BD section for the procedure to replace
an SNI.)
3. If no LEDs light on any board in the same carrier, fix any connectivity
problems between this carrier and the media server. Use list
fiber-link to determine the fiber connections to this carrier. Check
the LEDs on every SNI and EI, and fix any fiber problems. Enter
display errors, and resolve any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
Table 438: Test #756 SNI Off-Board Destructive Facility Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3