MAINT (PN’s Maintenance Circuit Pack)
Issue 1 June 2005 1495
Table 536: Test #106 Sanity Handshake Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to cabinet query was not received in the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2033 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2046 ABRT The PN’s Maintenance circuit pack reported an invalid cabinet type. Not
knowing the cabinet type of the PN will prevent all PN environment
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the PN’s
Maintenance circuit pack is defective, or the PN cabinet’s wiring is
defective. First, replace the Maintenance circuit pack.
3. If the test continues to abort with 2046, then the PN cabinet’s wiring
is defective in the A carrier, and the PN’s Maintenance circuit pack
cannot read the backplane pins to determine the cabinet type.
10601 ABRT Test disabled via software patch.