1005 ABRT The test aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, a modem pool member or Music on Hold). This error
can be ignored.
1018 ABRT The test is disabled.
1. Enable maintenance by entering y in the Maintenance Tests field on
page 2 of the change trunk-group screen.
1113 ABRT The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State test).
1114 ABRT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116 ABRT The trunk is not in a service state which is appropriate for running the test.
This test is only performed in the OOS/FE state.
1117 ABRT A service state audit message is outstanding.
1. Wait two minutes and then try again.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
PASS Wait 4 minutes and then check the Error Log for any new errors of type
3073. If there are none, then both sides of the ISDN connection agree on the
service state; the negotiation succeeded. If there is a new 3073 error, then
the negotiation failed (the far-end switch twice failed to respond within 2
minutes). The switch automatically retries every 15 minutes. If the trunk was
initially in-service, it is now placed in the maintenance/far-end state.
Incoming calls are accepted, but no outgoing calls can be originated. If an
incoming call is presented, another Service State Audit is immediately
performed in an attempt to put the TN2185 Trunk-Side ISDN-BRI channel in
the proper state.
Table 798: Test #256 Service State Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2