TDM-CLK (TDM Bus Clock)
Issue 1 June 2005 2259
Notes:
a. See XXX-BD (Common Port Circuit Pack/Media Module)
on page 2539 for a descriptions of
this test.
b. See TONE-BD (Tone-Clock Circuit)
on page 2327 for a description of this test.
c. See TONE-PT (Tone Generator)
on page 2353 for descriptions of this test.
d.
S8700 MC:This test only runs on the standby IPSI or Tone-Clock circuit pack in a port
network with more than one IPSI or Tone-Clock circuit pack (high- or critical-reliability
option). The Tone-Clock circuit pack must be a TN780 code with firmware revision 2 or
above, or be a TN2182.
e. Test #149 is not run on the TN2182.
TDM bus Clock Circuit Status Inquiry Test (#148)
The TDM bus Clock circuitry is checked for sanity. Error codes show any problems that are
found.
Table 808: Test #148 TDM bus Clock Circuit Status Inquiry Test
Error
Code
Test
Result
Description / Recommendation
None
1001
ABRT The system could not allocate the necessary resources for the test.
1. Wait 1-minute, and retry the test.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3