Communication Manager Maintenance-Object Repair Procedures
1312 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Tone Detector Audit/Update Test (#43)
The GPTD port is refreshed with all time-slot information, and a sanity audit is performed on the
GPTD port.
Table 453: Test #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT The system was not able to allocate the resources needed for this test.
1. Wait 1 minute and try again.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Hardware audit failed.
1. Run the short test sequence: test port location short
repeat 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. To restore the system performance to normal,
replace the Tone Detector circuit pack containing the defective GPTD
port.
PASS The GPTD port has been successfully refreshed with its translation.