ATM-SGRP (ATM Signaling Group)
Issue 1 June 2005 599
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: switch sent a message to the far-end switch or terminal adapter, and the far
end did not respond in the allotted time. Possible causes include link failure and congestion
or outage at the far end. The Aux Data field contains layer-3 protocol information used by
internal counters.
If no other symptoms are present, no action is required. If layer-3 communication is down:
a. Check for alarms and errors against link components
2. Check out other errors against ATM-SGRP, ATM-TRK, and other hardware components on
the link.
There is no test to clear these errors. The error counter is decremented by 1 every 15
minutes.
Table 196: ATM-SGRP Signaling Group Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
00 Any Any test sig-group grp#
1 (a
) Any None
18 (c
) MO busied out
257 (d
) Any None test sig-group grp#
769 (e
) Any Primary Signaling Link
Hardware check (#636)
test sig-group grp#
1281
(f
)
Any Secondary Signaling Link
Hardware check (#639)
test sig-group grp#
1793
(g
)
Any Layer 2 Status test (#647) WRN OFF test sig-group grp#
2305
(h
)
Any Remote Layer 3 Query test
(#637)
MIN OFF test sig-group grp#
3585
(i
)
Port
number
None
3840 -
3928
(j
)
Port
number
None