ALARM-PT (Alarm Port)
Issue 1 June 2005 381
Station Status and Translation Audits and Updates Test (#36)
Port Updates Test (#36)
For an analog line port that is administered as an external alarm, this test is limited to updating
the software with the switchhook state.
This test sends port level translation data from switch processor to the circuit pack to assure
that the translation is correct. The port audit operation verifies the consistency of the current
state of the port in the switch software.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. enter list
config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1
, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
this is not the case, check to ensure that there is a valid board inserted.
Table 110: Test #35 Battery Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 111: Test #36 Station Status and Translation Audits and Updates
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3