PMS-LINK (Property Management System Link)
Issue 1 June 2005 1845
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to the extension
where the PMS device connects. If the PMS Link is already up, then this test passes without
making any data call.
Table 677: Test #215 Link Retry Test
Error
Code
Test
Result
Description / Recommendation
10
20
ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30 ABRT Internal system error.
1. Refer back to Procedures for Restoring the PMS Link
on page 1840
for resolution.
1010 ABRT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link to release the PMS Link from busyout
state.
2. Retry test pms-link to execute the test.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The PMS Link CANNOT be established.
1. Refer back to Procedures for Restoring the PMS Link
on page 1840
for restoring the PMS Link.
PASS The PMS Link is up.