Communication Manager Maintenance-Object Repair Procedures
2430 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Major Alarm Inquiry Test (#142)
The Major Alarm Inquiry test is used to determine if the received DS1 bit error rate is greater
than 1/1000. The UDS1 Interface circuit pack takes 10 seconds to recognize and report a Major
alarm and 10 seconds to recognize and report that a Major alarm condition is cleared.
When the UDS1 Interface circuit pack detects a Major alarm, it sends a MAJOR-ALARM
message to the maintenance software. (32-channel interfaces send a YELLOW alarm to the far
end). After the maintenance software receives a MAJOR alarm message, the Major Alarm
Inquiry test is initiated to confirm the Major alarm on the UDS1 Interface circuit pack. The
Inquiry test runs every 10 minutes until the Major alarm is cleared. The maintenance software
places every trunk or port on the circuit pack in the out-of-service state if the Major alarm
persists for more than 20 minutes.
When the Major alarm is cleared, the maintenance software restores every trunk or port on the
circuit pack to its previous service state before a Major alarm occurs.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1
location to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board is shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter
busyout board location
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 861: Test #141 Yellow Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 5