TONE-PT (Tone Generator)
Issue 1 June 2005 2361
Tone Generator Crosstalk Test (#90)
This test checks the ability of the Tone Generator to talk on a specific time slot. The tone
generator is told to talk on a specific time slot. The other idle time slots are checked to make
sure the Tone Generator put the tone on only the specified time slot.
1 FAIL The system requires a TN780, TN2182, or TN2312 Tone-Clock circuit to
support the administered tone-generation parameters.
1. Check the administration on the tone-generation screen.
Specifically, the Base Tone Generation Set on page 1 and any custom
tone administration beginning on page 2.
2. Replace any existing IPSI with a TN2312., or an existing Tone-Clock
circuits packs with a TN780 or TN2182.
PASS The tone generation facility has been successfully refreshed with its
time-slot translation and system administration is consistent with this type
of Tone-Clock.
1. Display the Hardware Error Log using display errors to make sure
this circuit pack did not generate new errors.
Table 844: Test #41 Tone Generator Update/Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2
Table 845: Test #90 Tone Generator Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
None ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1001 ABRT The system was not able to put the tone generation facility in the
appropriate mode to test it.
1002 ABRT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS using test tdm port-network P.