Table 665: Test #572 Maintenance/Test Circuit Pack Query Test
Error
Code
Test
Result
Description / Recommendation
1006 ABRT The packet bus port of the Maintenance/Test circuit pack is out of service.
1. Determine whether the port is busied out. If so, release it with
release port location04. Then retry the test command.
2. If there are alarms active against the packet bus port (MT-PKT), see
M/T-PKT (Maintenance/Test Packet Bus Port)
on page 1722 to
resolve them. Then retry the test command.
1142 ABRT No Maintenance/Test circuit pack packet bus port is in service in this PN.
1. If this PN is required by configuration guidelines to have a
Maintenance/Test circuit pack:
the Maintenance/Test circuit pack for this PN has failed, and
should be replaced,
the Maintenance/Test circuit pack has been busied out, and should
be released, or
there is no Maintenance/Test circuit pack in this PN, and one must
be installed.
2. In a PN of a system without PNC duplication, the Maintenance/Test
packet bus Port is not required and may not be present. If it is
present, and is busied out, or has failed, release or replace the circuit
pack. If there is no Maintenance/Test circuit pack, ignore the results of
this test for this PN.
2000 ABRT The test timed-out while waiting for an uplink CCMS response from the
Maintenance/Test packet bus port.
1. Re-enter the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, check for problems with the
Maintenance/Test packet bus port (look for M/T-PKT in the Error and
Alarm Logs).
2059 ABRT The Maintenance/Test packet bus port has reported a hardware failure.
1. See M/T-PKT (Maintenance/Test Packet Bus Port)
on page 1722 to
correct the problem.
2. Re-enter the test command.
1 of 3