Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
NR-CONN (Network-Region Connect)
Issue 1 June 2005 1733
Network Region Interconnectivity Test (#1417)
This test is nondestructive.
Test #1417 is a nonstandard test, since it does not specify and list Error Codes in the usual
manner. If this background test detects a failure, the test is retried using different IP endpoints (if
available) from the same two network regions. If the test still fails between these network
regions:
1. Maintenance software marks the connectivity between them as “failed.”
2. Communication Manager denies every attempted call between them.
For this test, devices that can serve as IP endpoints include:
IPMEDPRO
MEDPRO
CLAN-BD
IP phones or Softphones, with the ability to initiate a ping
For a network region without an IPMEDPRO, MEDPRO, or a CLAN-BD, Test #1417 looks for
another ping-capable endpoint. If found, the region’s testing continues. If not, the test assumes
that the region’s connectivity is okay.
Table 642: Test #1417 Network Region Interconnectivity Test
Error
Code
Test
Result
Description / Recommendation
1
2
11
ABRT Internal error
1. Retry the command at 1-minute intervals up to 3 times.
2. If the problem persists, escalate the problem.
1005 ABRT Incorrect test configuration.
1. Verify Ethernet link is in service on all CLAN boards in source and
destination with status port location or status link n).
1125 ABRT Ethernet link not in service.
1. Verify Ethernet link is in service for all CLAN boards in the source
and destination regions under test using status port location
or status link n. If interface is enabled, the ethernet link is
expected to be in-service for this test to run.
1 of 3