PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005 1779
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description and follow its procedures.
b. Error Type 1: disagreement between this switch and the terminal adapter at the other end
of the connection with regard to the ISDN call state of the PRI endpoint port. This switch will
automatically try to recover by clearing the call (the call will be torn down). Use status
pri-endpoint extension to determine the state of the port.
When running the short test sequence, pay close attention to the results of the Call State
Audit test (#257).
c. Error Type 15: software audit error that does not indicate any hardware malfunction. Run
the short test sequence, and investigate associated errors.
18 (d
)0busyout
pri-endpoint
extension
busyout port
location
release pri-endpoint
extension
release port location
129 (e
)None WRNOFFtest port location sh r 1
130 (f
)None WRNONtest port location sh
257 (g
)AnyNone test port location sh r 1
513 (h
) Any None WRN OFF test port location sh r 1
769 (g
)AnyNone test port location sh r 1
1281 (i
) Any Conference Circuit
test (#7)
MIN ON test port location l r 4
1537 (j
) Any NPE Crosstalk test
(#6)
MIN ON test port location l r 3
1793 (k
)AnyNone test port location sh r 1
3073 (l
) Any Service State audit
(#256)
test port location sh r 2
3585 (m
) Any None None
Table 656: PRI endpoint port Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2