EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005 1199
When testing of the EI is not possible, (for example, when the PN is down), see the previous EI
Manual Loop-Back procedure.
Expansion Interface Neighbor Query Test (#237)
This test is nondestructive.
The Expansion Interface Neighbor Query test is a request to an EI circuit pack to determine
whether it has established communication with its neighbor EI or SNI circuit pack.
Table 409: Test #237 Expansion Interface Neighbor Query Test
Error
Code
Test
Result
Description / Recommendation
1033 ABRT The EI circuit pack does not have a fiber link administered to it. There is
not sufficient data to run test.
1. Enter list fiber-link to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack, but there should be
add the correct fiber using add fiber-link.
3. Retry the command.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2031 ABRT The attempt to send the message to the EI circuit pack, asking it who it’s
neighbor is, was not successful.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT System resources required to run this test are not available. Someone
may be doing something on this Port Network Interface.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.