Communication Manager Maintenance-Object Repair Procedures
718 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
q. Error 2568: the adjunct ID is invalid, check the vender ID or software running on the Avaya
adjunct.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors associated with the circuit pack and port first. Clearing these error codes first
may also clear errors generated against the endpoint. When every circuit pack and port error
has been cleared, and errors still exist against the endpoint, investigate errors in the order they
are presented in the table below. By clearing error codes associated with the Signaling Link
Status test (#626), you may also clear errors generated from other tests in the sequence.
58 Bearer
Capability Not
Currently
Available
Requested bearer capability is implemented, but not administered.
No B channel is administered. See recommendation for Error Code
50 above.
65 Bearer
Service Not
Implemented
Requested service not implemented in switch or endpoint.
69 Requested
Facility Not
Implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine
service support.
2. If step 1 does not resolve the problem, escalate to the next tier.
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and
the adjunct. Refer to the CallVisor protocol reference manual.
2. If step 1 does not resolve the problem, escalate to the next tier.
Table 242: ISDN-BRI CAUSE VALUES; (BRI-SET/ASAI-ADJ Error Log Notes) (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
Signaling Link Status test (#626) X X ND
BRI XID test (#628) X X ND
BRI Layer 3 Query (#629) X(a) X(a) ND
1 of 2