Communication Manager Maintenance-Object Repair Procedures
2524 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the number of VC resources in the system that are in service has fallen below
the calculated minimum value. If the number of in-service VC ports falls below the MMCH
port capacity (value entered in the Minimum Maintenance Threshold VCs field on the
system parameters maintenance screen), a VEC-LEV error is logged.
If this outage continues for 15 minutes a MAJOR alarm is raised. To resolve this alarm,
correct the out-of-service problem:
1. See VC-DSPPT
on page 2513 and VC-BD on page 2509 to resolve any associated
alarms.
2. If a VC-LEV error/alarm exist and none has been raised against VC-BD or VC-DSPPT
MOs, a VC circuit pack may have been removed from service causing the VC-LEV error/
alarm. To resolve a VC-LEV MAJOR alarm, restore the number of VC ports available for
service to be equal to or more than the calculated port capacity. See Resolving VC-LEV
Errors/Alarms on page 2522 for details.
System Technician-Demanded Tests:
Descriptions and Error Code
There are no System Technician-Demanded test for VC-LEV.
Table 896: VC-LEV Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
1 (a
) Any None MAJ OFF