IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005 1383
Notes:
a. Error Type 1: the circuit pack has been removed from the system or is not fully
administered. The alarm is logged about 15 minutes after the circuit pack has been
removed, or 11 minutes after the SAKI test (#53) fails.
To be fully administered, an IP Media Resource must:
● Have an entry on the circuit pack screen (change circuit-pack)
● Have the Media Resource IP address administered (change node-names)
● Be enabled (change ip-interface)
● Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are
not met, a MINOR alarm is logged. To resolve the error:
● Make sure every condition for administration is met, and that a functioning Media
Resource is inserted in the correct slot.
● Completely remove the IP Media Resource from the system:
a. Remove the administered IP-Interface associated with the circuit pack.
3073 (o
) Any Aggregator
Hardware Query
(#1629)
MIN ON
3329 (p
) Any Duplicate
network IP
address detected
(#1371)
MIN OFF
3585 (q
) 1 or 2 Verify NIC option
test (#1511)
MIN OFF
3841(r
) None Inconsistent
downlink or
board error
3841(s
) 4283 RTCP Monitor
Server error
3999 (t
) Any None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on values set in set options.
Table 485: TN2602AP IP Media Resource Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
3 of 3