SNI-BD (SNI Circuit Pack)
Issue 1 June 2005 2063
104 FAIL The SNI circuit pack cannot communicate with the SNI in slot 4 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 4.
Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Follow
the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 513. If other SNI circuit packs have
SNI-PEER Error Type 513, then replace the SNI in slot 4. Replacing
an SNI may be service interrupting. See SNI-BD (SNI Circuit Pack)
on
page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 513 errors, the
problem could be at either of the peer SNI boards. It is arbitrary as to which
SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 4.
105 FAIL The SNI circuit pack cannot communicate with the SNI in slot 5 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 5.
Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Then
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 769. If other SNI circuit packs have
SNI-PEER Error Type 769, then replace the SNI in slot 5. Replacing
an SNI may be service interrupting. See SNI-BD (SNI Circuit Pack)
on
page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 769 errors, the
problem could be at either of the peer SNI boards. It is arbitrary as to which
SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 5.
Table 749: TEST #755 SNI Circuit Path Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 11