Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
SN-CONF (Switch Node Configuration)
Issue 1 June 2005 1993
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 5000: at least one administered circuit pack in this switch node carrier was not
inserted, or one or more administered circuit packs in this switch node carrier did not
respond to Test 760 with a “board insertion” uplink message.
To resolve this error, run test 760 using test board location l for an SNC in the same
switch node carrier that has this error.
Table 736: SN-CONF Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test board location sh r 1
5000 (b
) Any Processor Route Audit (#760) MIN OFF test board location l rep 1
6000 (c
) 1 Configuration Audit (#759) MAJ OFF test board location rep 1
6000 (c
) 2 Configuration Audit (#759) MAJ OFF test board location rep 1
6001 (d
) Any Configuration Audit (#759) MAJ OFF test board location rep 1
6002 (e
) 1 Configuration Audit (#759) MAJ OFF test board location rep 1
6002 (e
) 2 Configuration Audit (#759) MAJ OFF test board location rep 1
6003 (f
) Any Configuration Audit (#759) MAJ OFF test board location rep 1
6004 (g
) Any Configuration Audit (#759) MAJ OFF test board location rep 1
6005 (h
) Any Configuration Audit (#759) MAJ OFF test board location rep 1
6005 (h
) 1 Configuration Audit (#759) MAJ OFF test board location rep 1
6005 (h
) 2 Configuration Audit (#759) MAJ OFF test board location rep 1
6006 (i
) Any Configuration Audit (#759) MIN OFF test board location rep 1
6007 (j
) Any Configuration Audit (#759) MIN OFF test board location rep 1