Communication Manager Maintenance-Object Repair Procedures
1650 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
MG-ICC (Internal Call Controller)
S8700 | 8710 / S8500 / S8300 / G700
This maintenance object monitors the H.323 link between the S8300 Media Server running as
an LSP or as the primary call controller. It logs errors when the Keep Alive messages that are
exchanged between the servers fail. These messages indicate the status of the H.323 link
between the two. If the Keep Alive messages are active all is well; if not, an error is logged on
the LSP only.
Error log entry and test to clear value
System Technician-Demanded Tests: Descriptions and Error
Codes
There are no System Technician-Demanded Tests associated with this MO.
MO Name in
Alarm Log
Alarm
Level
Initial Command to Run Full Name of MO
MG-ICC MAJ None INTERNAL CALL CONTROLLER
Table 609: MG-ICC error log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
1 None MAJ OFF
Error Type 1 indicates a failure of the H.323 link keep alive messages between the LSP
and primary call controller. This is an indication that the LAN or the primary call controller is
down.