ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005 557
ATM Board Error Query Test (#1259)
This test is nondestructive. The ATM circuit pack firmware maintains counters for some of the
on- and off-board errors. The maintenance software queries the board for its health information
to do error analysis. These alarms have assigned priority: if a higher priority alarm occurs, the
remaining alarms are not reported to the software (through the inline errors), avoiding
unnecessary up-link, in-line error message traffic. This is run as a part of a craft demand test
sequence periodic testing, initialization, and error analysis.
Table 178: ATM Board Error Query Test (#1259)
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response to the test was not received within the allowable time period.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
XXYY FAIL On-board hardware or off-board signaling errors on the board. XX
indicates the on-board hardware error, and YY indicates the off-board
errors on the as shown in Table 179: XX Error Codes, Test #1259 (ATM
Board Error Query Test) on page 558 or Table 180: YY Error Codes, Test
#1259 (ATM Board Error Query Test) on page 559.
1. Resolve any errors in error logs.
PASS No service effecting errors or alarms were detected on the circuit pack.
0
NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board
(Error Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error Type 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, the NCE chip on board could be bad.
Replace the board and retest.