CO-TRK (Analog CO Trunk)
Issue 1 June 2005 861
1947 ABRT Noise with tone self check failed.
1. Test the TN771 circuit packs or.
2000 ABRT The test timed out while waiting for a response from the TN771 circuit
pack.
Retry the command at 1-minute intervals up to 5 times.
2012 ABRT An internal software error occurred.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABRT The test call could not be established, but an explanation is unavailable.
1. Retry the command at 1-minute intervals up to 5 times.
2056 ABRT An error occurred while trying to obtain results from the TN771 circuit pack.
Test the TN771 circuit packs.
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group screen. Retrieve a measurement report via
list testcalls. Make sure that ATMS thresholds are set properly on
page 4 of the trunk group screen. Besides the facility, test failures can be
caused by faulty test lines or switch paths. If the measurements point to a
facility problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal range as
administered on the trunk group screen. This generally means that the
trunk is usable but has an undesirable amount of noise or loss. If the user
does not report unacceptable effects, it may not be necessary to take any
action. Retrieve a measurement report via list testcalls. Make sure
that ATMS thresholds are set properly on page 4 of the trunk group screen.
Table 293: Test #844-848 Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 4