DAT-LINE (Data Line Port)
Issue 1 June 2005 875
Audit Update Test (#36)
This audit verifies that the hardware state of the data line is consistent with the system
translations. The audit queries the port for the switchhook state, the software state is updated
according to the returned value. Also, the audit data line options down to the port.
Table 299: Test #36 Audit Update Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
1006 ABRT An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type
#769.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
ABRT Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
7 FAIL Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
PASS The hardware port state is consistent with the software state. Investigate
user-reported troubles on this port using other port tests and examining the
ADU, external wiring, and customer equipment.