Issue 1 June 2005 731
BRI Set Audits Test (#630)
This is a series of two tests that are classified as audits. The switch sends messages to the BRI
endpoint to perform the following tests:
Ringer Audit – This audit insures that both the switch and the endpoint agree as to the
current state of the endpoint’s ringer.
Lamps Audit – This audit insures that both the switch and the endpoint agree as to the
current state of the endpoint’s lamps.
Call Activity Audit – This audit insures that the state of calls is consistent between the
switch and the endpoint.
This test is not executed for ASAI or Avaya adjunct because adjuncts do not employ ringers or
lamps, or establish calls on the B channels associated with the BRI interface.
Table 247: Test #630 BRI Set Audits
Error
Code
Test
Result
Description / Recommendation
1113 ABRT The signaling link between the switch and the endpoint is down.
1. Use test port location long to clear any errors that prevent
establishment of the signaling link.
2. Examine the results of the Signaling Link Status test (#626) that is run
as part of this command. If this test aborts or fails, follow the repair
procedure for Test #626.
3. If the BRI Set Audits test continues to abort, escalate the problem.
1139 ABRT The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute test port location long and
review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
1141 ABRT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.