Server Alarms
50 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
(Table 13: DAJ1/DAL1 Alarms in Media Server on page 54 describes the Duplication Memory
board’s alarms and their troubleshooting procedures.) [See also, ARB (Arbiter)
on page 37,
DUP (Duplication Manager)
on page 56, and NIC (Network Interface Card) on page 75.]
Both periodic and on-demand testing is provided for this MO. The periodic test runs the Read
Error Register test at 15-minute intervals. On-demand testing includes the Read Error Register
and Local Loop tests.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Linux Command to Run Full Name of MO
DAJ1 or DAL1 MAJ testdupboard
1
1. See Table 9
Server Dup Mem board
DAJ1 or DAL1 MIN testdupboard Server Dup Mem board
DAJ1 or DAL1 WRN testdupboard Server Dup Mem board
Table 9: Testdupboard command syntax and arguments
Argument Description
Syntax: testdupboard [-s] | [-l] | [-t arg] | [-?]
no
argument
Performs “short” test.
-s Short test, performs read_err_reg test, this is also the default option.
-l Performs “short” tests, and localloop test
-t arg Specific test to perform. Possible values for arg are:
● read_err_reg
● localloop.
-? Usage (this).