Communication Manager Maintenance-Object Repair Procedures
2402 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1005 ABRT Wrong circuit pack configuration to run this test. This error applies only to
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is
providing timing for the system, and therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to
another DS1 Interface circuit pack or to the IPSI or Tone-Clock circuit
pack and try again. See SYNC (Port-Network Synchronization)
on
page 2143.
1015 ABRT Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute reset board location again.
2100 ABRT System resources required for this test are not available.
1. Retry the reset board location at 1-minute intervals up to 5
times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute reset board location again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the short test sequence.
Table 856: Test #53 SAKI Sanity Test (continued)
Error
Code
Test
Result
Description / Recommendation