DTMR-PT (Dual-Tone Multifrequency Receiver Port)
Issue 1 June 2005 1119
Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time-slot information, and sanity audit is performed on the
DTMR port.
Table 381: Test #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description / Recommendation
None ABRT The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute and try again.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Hardware audit failed.
1. Run the short test sequence: test port location sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore the system performance to
normal, replace the Tone Detector or IPSI circuit pack containing the
defective DTMR port.
PASS The DTMR port has been successfully refreshed with its translation.