Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1866 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
m. Error Type 11300 – 11363: a spontaneous PNC interchange took place in response to the
occurrence of a major or minor alarm on the A-PNC associated with fault class FC_PER.
This indicates one or more faults on peer links that connect SNIs to EIs. Investigate any
alarms against SNI-PEER. Adding 1 to the last two digits of the Error Code gives the PN
number of the port network that reported the alarm. (11303 points to port network 4.) Use
list config port-network to show the cabinet number associated with a port
network.
n. Error Type 11400 – 11463: a spontaneous PNC interchange took place in response to the
occurrence of a major or minor alarm on the A-PNC associated with fault class FC_DS1.
This indicates faults on one or more DS1C facilities. Investigate any alarms against
DS1-FAC. Adding 1 to the last two digits of the Error Code gives the PN number of the port
network that reported the alarm. (11403 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.
o. Error Type 11601 – 11664: a spontaneous PNC interchange took place in response to the
occurrence of a major or minor alarm on the A-PNC associated with fault class FC_SNIL.
This indicates one or more faults on peer or neighbor links between SNIs on different switch
nodes. Investigate any alarms against SNI-PEER. The last two digits of the Error Code
indicate the fiber-link number of the fiber that reported the retired alarm. Use list
fiber-link to show the location of the fiber.
p. Error Type 11701 – 11764: a spontaneous PNC interchange took place in response to the
occurrence of a major or minor alarm on the A-PNC associated with fault class FC_SNIHW.
This indicates one or more faults on hardware connecting SNIs on different switch nodes.
Investigate any alarms against SN-CONF, SNI-BD, FIBER-LK. The last two digits of the
Error Code indicate the fiber-link number of the fiber that reported the retired alarm. Use
list fiber-link to show the location of the fiber.
q. Error Type 20000 – 20063: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the B-PNC associated with fault class FC_EAL. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (20003 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.
r. Error Type 20100 – 20163: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the B-PNC associated with fault class FC_INL. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (20103 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.
s. Error Type 20200 – 20263: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the B-PNC associated with fault class FC_HW. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (20203 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.