Communication Manager Maintenance-Object Repair Procedures
946 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
DIG-LINE Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run only if the
station is in-service. The status of the station is checked and the lamp updates are blocked from
taking place if the station is not in the in-service state. This test does not affect the status of the
Message Waiting lamp.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
15 FAIL The control channel between the processor and digital circuit pack is not
transmitting properly. User impact may range from noticing nothing to not
being able to use the port. Could also be disruptive to other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit and the Tone
Detector circuit using test board location.
2. Resolve any problems that are detected on the Tone Generator circuit
or Tone Detector circuit.
3. If the Tone Generator and Tone Detector circuit are functioning
properly, and the test still fails, replace the Digital Line circuit pack.
PASS Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times.
2. If complaints persist (noisy connections for voice, corrupted data for
data transfer), examine the station, connections, and wiring.
Table 323: Test #13 Voice and Control Channel Local Loop Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 324: Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3