Communication Manager Maintenance-Object Repair Procedures
896 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Port Audit and Update Test (#36)
This test sends port-level translation data from the switch processor to the DS1 Interface circuit
pack or media module to assure that a trunk’s translations are correct. The port audit operation
verifies the consistency of the current state of the trunk as kept in the DS1 Interface circuit pack
or media module and in switch software.
Table 306: Test #36 Port Audit and Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT The port may be busy with a valid call.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error
log for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1006 ABRT The test was aborted because the trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. To put the trunk back in service, enter release trunk. Retry the test.
2000 ABRT Response to the test was not received in the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2