MEDPROPT (TN802/TN2302/TN2602 MED PRO DSP PORT)
Issue 1 June 2005 1559
DSP Port Status Query Test (#1407)
This test is nondestructive.
This test queries the state of the DSP port.
Table 575: DSP Port Status Query Test (#1407)
Error
Code
Test
Result
Description / Recommendation
1 ABRT This port is Out of service (OOS) due to:
A board-level problem, for example no IP address has been
translated for this location.
A DSP hardware problem (see DSP Port TDM Loop-Around Test
(#1380) on page 1557 and DSP Query Test (#1382) on
page 1555).
2 ABRT This port has been made maintenance busy.
1002 ABRT The system could not allocate timeslots for the test. The system may be
under heavy traffic conditions, or it may have timeslots out of service
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals up to 3 times.
2. If the system has TDM-BUS errors, clear any errors, and retry the
command at 1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
2000 ABRT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL Unable to get status for this port. Verify that this board has been
administered correctly, and that there are no alarms against this board.
PASS The board is functioning properly and the port is in-service and available.
0NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131)
issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, replace the board and retest.