BRI-SET, Various Adjuncts
Issue 1 June 2005 729
1187 ABRT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station
via release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via release port location and run the
test again. If the error is present for BRI-SET only, then release the
circuit pack via release port location and run the test again.
If the error is present for both BRI-BD and BRI-PORT, then release
the circuit pack via release board location and run the test
again.
Note:
Note: When you release the circuit pack, you release every port
associated with it. If certain ports still need to be busied out,
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012 ABRT Internal system error.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2068 ABRT The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Endpoint Service messages.
1. Use change station extension and change the MIMs Supported
field to n.
Table 246: Test #629 BRI Layer 3 Query (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4