SYSTEM (System)
Issue 1 June 2005 2187
Notes:
a. Error Type 9: software requested a System Restart Level 2.
b. Error Type 10: software requested a System Restart Level 1.
c. Error Type 601: an error occurred during initialization.
d. Error Type 605: a reset system interchange or a scheduled server interchange
failed. The AUX Data indicates the cause of the failure. Consult the table in note p. Enter
the Linux server command to determine the current server status, and resolve any
problems on the standby server that are preventing the server interchange.
e. Error Type 606: a reset system interchange health-override failed. The
standby server’s state of health (SOH) would not allow a spontaneous server interchange.
Enter the Linux server command to determine the current server status, and resolve any
problems on the standby server that are preventing the server interchange.
f. Error Type 6001: an operating system error occurred on the active server. The Aux Data
gives the source of the error:
g. Error 6002: an application error occurred on the active server. See note (l
) to diagnose the
error using the Aux Data.
h. Error 6003: an application alarm occurred on the active server. See note (l
) to diagnose the
error using the Aux Data.
i. Error 6100: an operating system error occurred on the standby server. See error 6001 (g)
to interpret the Aux Data.
j. Error 6102: an application error occurred on the standby server. See note (l
) to diagnose
the error using the Aux Data.
6101 (i
) Any None
6102 (j
)(l)(l) None
6103 (k
)(l)(l) None
Aux Data Operating System Error Type
5 Software Abort
6 Server Bus Error
Table 780: System Error Log Entries (continued)
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2