Communication Manager Maintenance-Object Repair Procedures
1796 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2077 ABRT The Maintenance/Test Circuit Pack Query located more than one
Maintenance/Test packet bus port in the PN.
The software should not allow this to occur. This is an internal system
error. Escalate the problem, but also attempt the following work-around
steps.
1. Remove every Maintenance/Test circuit pack from the PN.
2. Insert one Maintenance/Test circuit pack (there should not be more
than one in a PN).
3. Re-enter the test command.
2100 ABRT Maintenance could not allocate every necessary system resource to
perform this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The Maintenance/Test packet bus port has detected faults on the Packet
Bus. The Error Codes are interpreted as follows:
Table 665: Test #572 Maintenance/Test Circuit Pack Query Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3