Communication Manager Maintenance-Object Repair Procedures
1552 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
● Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are
not met, a MINOR alarm is logged. To resolve the error:
● Make sure every condition for administration is met, and that a functioning Media
Resource is inserted in the correct slot.
● Completely remove the IP Media Resource from the system:
a. Remove the administered IP-Interface associated with the circuit pack.
b. Physically remove the circuit pack from the slot.
b. Error Type 1000210012: Simplex mode downlink. The reason for the state interchange to
active was a Simplex mode downlink to the circuit pack. When the board is inserted and
before it is used for any bearer traffic, the server configures the board to operate either in
Simplex or Duplex mode via a downlink message. That operation may trigger the
interchange.