Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
674 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
AXA12-RS (AUDIX Reserve Slots)
Error log entries and tests also apply to ADX8D-RD and AXD12-RS.
S8700 MC
There are no tests associated with these MOs. Both test board and busyout board abort
when either is attempted on a reserved slot. An error message indicates that the slot is
associated with the circuit pack that the TN568 is emulating, but the requested operation is not
valid. If there are errors logged against these MOs, see XXX-BD (Common Port Circuit Pack/
Media Module) on page 2539.
The TN568 circuit pack connects to the switch through a single slot in the backplane; however,
the number of slots physically occupied by the circuit pack is supplied by the board when
inserted. The TN568 is 2 slots wide: the functional slot and a reserve slot. The reserve (blank)
slot to the left of the functional slot is a place holder on the switch and has no interaction with
the switch.
These MOs are place holders for the extra slot needed for the EMBEDDED AUDIX board.
Each instance of these MOs represents a reserve slot associated with the respective circuit
pack mode in which the TN568 (EMBEDDED AUDIX) is working. They are used for
EMBEDDED AUDIX and emulation of respective port types.
MO Name in
Alarm Log
Alarm
Level
Initial Command to Run Full Name of MO
AXA12-RS NONE NONE TN568 12-port analog
reserve slot
ADX8D-RS NONE NONE TN568 8-port digital reserve
slot
AXD12-RS NONE NONE TN568 12-port digital
reserve slot