Communication Manager Maintenance-Object Repair Procedures
396 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1 FAIL This does not indicate a hardware problem. The switchhook audit failed.
The other updates were not performed because of this failure. This may
occur when the audit is performed at the same time the terminal equipment
goes off-hook.
1. Use status station to determine when the port is available.
2. Retry the command at 1-minute intervals up to 5 times.
5 FAIL This may be an internal software error. The message waiting lamp update
failed. The translation and ringer updates were not performed because of
this failure.
7 FAIL The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8 FAIL This does not indicate a hardware problem. There may be an internal
software error. The ringer update failed.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, or by examining the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Enter list config
and resolve problems.
2. If the board was found to be correctly inserted in step 1, enter busyout
board
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 116: Test #36 Station Status and Translation Audits and Updates (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2