RDIG-STA (Remote Digital Station)
Issue 1 June 2005 1939
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using display port, where the
display shows that the port is a TTI port, or list config, where the
display shows a t for the port.
2. If list config or display port indicate that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a
TTI port, the abort is correct, and no action is necessary.
2000 ABRT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Station audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 712: Test #17 Station (Digital) Audits Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2