AN-LN-PT (Analog Line Port)
Issue 1 June 2005 437
Station Status and Translation Audit and Update Test (#36)
This test updates the analog port’s message lamp state (if it has one) and translations with
information in the software.
PASS The port’s battery feed chip is able to provide sufficient power to the station
equipment to detect on-/off-hook, but may not be able to supply power for
touch-tones.
1. If touch-tones are inoperative on this station, replace the circuit pack or
media module, because this port is inoperative.
2. Investigate user-reported troubles on this port by running other port
tests, by examining station wiring, or by inspecting the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Enter
list configuration, and resolve any problems.
2. If the board is correctly inserted, enter busy board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the link between the internal ID and the port. If not,
verify that a valid board is inserted.
Table 128: Test #35 Battery Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 129: Test #36 Station Status and Translation Audit and Update
Error
Code
Test
Result
Description / Recommendation
ABRT Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1 of 3