Communication Manager Maintenance-Object Repair Procedures
504 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 155: Test #625 Receive FIFO Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response was not received from the circuit pack within the allowable time
period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack using
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.
2012 ABRT Internal system error
2100 ABRT Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The TN800 circuit pack is still detecting errors of this type. The Error Code
field contains the value of this counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, review the results of other tests in the long
test sequence. Note the results of the Level 1 Status Inquiry test.
Follow repair procedures for any of the tests that fail. Otherwise, go to
the next step.
3. If the tests for the endpoints or adjunct pass and the Layer 1
Transmission Error Counter test continues to fail, check the wiring to
the endpoints or adjunct.
PASS The Layer 1 Transmission error counter was read correctly and has a value
of 0.