Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005 2315
1006 ABRT (TN497 circuit pack only.) The port is in the out-of-service state. The test
cannot be run.
1. Retry the command once the port is in service.
2100 ABRT Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS This test passed. Translation information was successfully updated on
the circuit pack. If the trunk is busied out, the test does not run but returns
a PASS (except on TN439 and TN497).
1. If signaling troubles are reported, verify translation information for
this port.
(Non-TN497 circuit packs only.) If the trunk is busied out, the test
does not run, but it does return PASS.
2. To verify that the trunk is in-service, enter status trunk to verify
that the trunk is in-service. If the trunk is in-service, no further action
is necessary. If the trunk is out-of-service, continue to Step 2.
3. Enter release trunk to put trunk back into in-service.
4. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.
Table 831: Test #36 Audit Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2